BT200 BRAIN手操器是一種便攜設(shè)備,針對采用BRAIN通信協(xié)議的設(shè)備和現(xiàn)場儀表,對其進(jìn)行設(shè)定、更改、顯示、診斷和打印配置或校正信息。與橫河電機(jī)所有的通信設(shè)備一起使用
BT200 BRAIN手操器是一種便攜設(shè)備,針對采用BRAIN通信協(xié)議的設(shè)備,對其進(jìn)行設(shè)定、更改、顯示和打印參數(shù),如工位號、輸出模式、范圍等。這款手操器還可以監(jiān)視I/O值和自診斷結(jié)果,設(shè)定恒定電流的輸出以及進(jìn)行調(diào)零。當(dāng)系統(tǒng)啟動(dòng)或維持操作狀態(tài)時(shí),只需連接設(shè)備的4~20 mA DC信號線或ESC(信號調(diào)節(jié)通信卡)上的專用接口,即可執(zhí)行這些功能。
特性: BT200 BRAIN手操器
- |
自診斷/安全保護(hù)的錯(cuò)誤提示功能 |
|
此終端除了自診斷功能外,還具有維持重要設(shè)定數(shù)據(jù)完整性的編碼輸入功能。 |
- |
內(nèi)置熱敏打印機(jī) |
|
通過此選項(xiàng)功能,工位號、校正信息、配置信息等數(shù)據(jù)可以現(xiàn)場打印出來。用戶可以享用打印有質(zhì)量保證和符合ISO 9000的文檔的便利性。 |
As a portable terminal, the Model BT200 BRAIN TERMINAL is used in combination with equipment using brain communication for setting, changing, displaying and printing out parameters such as tag number, output mode, and range, through simultaneous communication. It also monitors I/O values and self-check results, sets constant-current output , and allows zero adjustments. The Model BT200 BRAIN TERMINAL is used by connecting it between 4 to 20 mA DC signal transmission lines of the equipment or to a dedicated connector on the ESC (Signal Conditioner Communication Card) when the system is started up or maintained.
FEATURES
Online monitoring and communication
The modulated communication signal does not interrupt the 4 to 20 mA DC signals during communication.
Common to all Yokogawa’s equipment
The Model BT200 BRAIN TERMINAL works with all equipment that uses BRAIN communication.
Easy of use
A large display (21 characters by 8 lines) eases setup and alteration procedures in English prompting interactive sequences.
Diagnostics/security with error messages
• Self-check function • Security code protection of setpoints • Low battery voltage alarm • Automatic power-off
Printer
(BT200-P00) Printer prints out tag numbers and other parameters on the spot.
STANDARD SPECIFICATIONS Equipment Specifications Applicable Equipment: [Field Instruments] DPharp ADMAG YEWFLO YTA [Signal Conditioner] Signal Conditioner for CENTUM Communication Specification: Yokogawa original protocol Modulation: Burst modulation 0: 2400 Hz 1: Signal without carrier Baud rate:1200bps Communication signal: host to device: +/- 0.5 V (load resistance 250 ) device to host: +/- 2 mA Communication Line: [Field Instruments] Load resistance: 250 to 600 (including cable resistance) Load capacitance: 0.22 μF or less Load inductance: 3.3 mH or less Power line spacing: 15 cm (6 inch) or more (Avoid parallel wiring.) [Signal Conditioner] Use dedicated cable Line Length: [Field Instruments] Up to 2 km (1.24 mile) (0.75 to 1.25 mm2 instrumentation cable) [Signal Conditioner] 1.1 m with dedicated cable Communication Signal Connection: Dedicated cable, 1.1 m long (3.6 ft)
EMC Conformity Standards EN61326-1 Class A, Table2 (For use in industrial locations) Display: LCD dot matrix, 21 characters×8 lines Controls: Membrane switches (four function keys, 20 general operation keys, and one power switch) Printer (BT200-P00): Thermal paper type Power Supply: Five AA 1.5 V dry alkali batteries (LR6/AM3 (N)), or Five AA 1.2 V Ni-MH batteries (HR6/AA) Dimensions: BT200-N00 . . . 228×110×51 mm (9.0×4.3×2.0 inch) BT200-P00 . . . 321×110×61 mm (12.6×4.3×2.4 inch) Approximate Weight: BT200-N00 . . . 510 g (1.12 lb) BT200-P00 . . . 700 g (1.54 lb)
NORMAL OPERATION CONDITIONS BT200-N00 Ambient Temperature: -15 to 55°C (5 to 131°F) Ambient Humidity: 5 to 95%RH at 40°C (104°F) BT200-P00 Ambient Temperature: 0 to 50°C (32 to 122°F) Ambient Humidity: 30 to 80%RH at 40°C (104°F) n STORAGE CONDITIONS Ambient Temperature: -15 to 60°C (5 to 140°F) Ambient Humidity: 5 to 95%RH at 40°C (104°F) 30 to 80%RH at 40°C (104°F) (with printer) n ACCESSORIES l Communication Cable: Two cables, one with alligator clips and one with IC clips (both snap-removable) l Handy carry case
n FUNCTIONAL SPECIFICATIONS Basic Functions: l Setup, alteration, and display of parameters BRAIN communication. : constant current output : Zero point adjustment Additional Functions: l Batch upload/download of data l Setpoint Protection: Security code entry is required to alter setpoints. l Battery Alarm: An alarm message appearing on the LCD announces low battery voltages. l Automatic Power-off: The terminal is switched off automatically if no key access is made for approximately 5 minutes. l LCD contrast adjustment l Printing (BT200-P00) Printout Information l All parameter lists l Parameter list within each menu item l Setup change data list l Uploaded data list l Display images l Self check list